CCSSV - CHEMIGUM TWO PART CEMENT 1895C, 1465C ACCELERATOR

  • MSDS: CCSSV
  • Manufacturer: ENGINEERED FABRICS CORP
  • Product Name: CHEMIGUM TWO PART CEMENT 1895C, 1465C ACCELERATOR
  • National Stock Number: 8040-00-439-3696
Product Identification

Product ID:CHEMIGUM TWO PART CEMENT 1895C, 1465C ACCELERATOR
MSDS Date:09/01/1993
FSC:8040
NIIN:00-439-3696
Kit Part:Y
MSDS Number: CCSSV

Responsible Party
ENGINEERED FABRICS CORP
669 GOODYEAR ST
ROCKMART, GA 30153
US

Emergency Phone: 216-379-8562;800-424-9300(CHEMTREC)

Info Phone: 770-684-7855

Preparer: WILLIAM RITTER

Cage: 0KDP8

Contractor
ENGINEERED FABRICS CORPORATION
548 ROCKMART, GA 30153 US

Telephone: 706-684-7855

Cage: 56221

Ingredients

2-BENZOTHAZOLETHIOL; (2-MERCAPTOBENZOTHIAZOLE)

CAS: 149-30-4

RTECS: DL6475000

Fraction By Weight: 50-55%

OSHA PEL N/K

ACGIH TLV: N/K


ETHANOL, 2-PROPOXY-; (2-PROPOXYETHANOL) (CONTAINING ING 3)

CAS: 2807-30-9

RTECS: KM2800000

Fraction By Weight: 40-45%

OSHA PEL N/K

ACGIH TLV: N/K


GLYCOL ETHERS

Fraction By Weight: <45%

OSHA PEL N/K

ACGIH TLV: N/K


BUTYRALDEHYDE, BUTYLAMINE REACTION PRODUCT; (CONDENSATION

CAS: 68411-19-8

Fraction By Weight: <5%

OSHA PEL N/K

ACGIH TLV: N/K


# 68411-19-89) (CONTAINING INGREDIENT 6)

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


BUTYRALDEHYDE (SARA 313)

CAS: 123-72-8

RTECS: ES2275000

Fraction By Weight: <1.0%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: PROPYL CELLOSOLVE CAN CAUSE
MODERATE TO SEVERE EYE IRRITATION AND MILD IRRITATION TO THE SKIN.
PROPYL CELLOSOLVE CAN BE ABSORBED THROUGH SKIN IN POTENTIALLY
HARMFUL AMOUNTS. INHALATION OF PROPY L CELLOSOLVE VAPORS MAY CAUSE
IRRITATION OF MUCOUS MEMBRANES, RED BLOOD CELL DAMAGE AND KIDNEY
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: INJURY. MAY CAUSE ALLERGIC SKIN
REACTION. CHRONIC: PROLONGED CONTACT WITH THE SKIN MAY RESULT IN
ABSORPTION OF ENOUGH PROPYL CELLOSOLVE TO CAUSE EFFECTS SIMILAR TO
THOSE WHICH MAY FOLLOW INH ALATION OR INGESTION OF PROPYL
CELLOSOLVE.
Medical Cond Aggravated by Exposure:PRE-EXISTING EYE, SKIN AND
RESPIRATORY DISORDERS MAY BE AFFECTED BY EXPOSURE TO THIS PRODUCT.

First Aid

First Aid:INHALATION: EXPOSE TO FRESH AIR. KEEP WARM AND QUIET. GIVE
ARTIFICIAL RESPIRATION IF BREATHING HAS STOPPED. SEEK MEDICAL
ATTENTION. EYES: FLUSH EYES WITH LARGE AMOUNTS OF WATER FOR AT
LEAST 15 MINUTES . CONSULT MD. SKIN: IMMEDIATELY FLUSH WITH WATER
WHILE REMOVING CONTAMINATED CLOTHING. INGESTION: IF CONSCIOUS, GIVE
TWO GLASSES OF WATER AND INDUCE VOMITING. SEEK MEDICAL ATTENTION
IMMEDIATELY.

Fire Fighting

Flash Point Method:TCC
Flash Point:94.0F,34.4C
Lower Limits:1.3%
Upper Limits:15.8%
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:UNKNOWN.

Accidental Release

Spill Release Procedures:REMOVE ALL IGNIT SOURCES. VENT THE AREA. WEAR
PERSONAL PROT EQUIP AS NEC. DIKE OR CONTAIN SPILL W/ABSORB OR OTHER
AVAIL MATLS. DO NOT ALLOW SPILL TO DISCHARGE INTO STORM/SANITARY
SEWERS. PUMP OR BAIL MATL BACK INTO ORIGINAL CNTNR OR
CLEAN,(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP THE CONTAINER TIGHTLY CLOSED TO
PREVENT EVAPORATION OF THE SOLVENT. KEEP AWAY FROM HEAT AND OPEN
FLAMES. STORE ACCORDING TO OSHA 29 CFR 1910.106.
Other Precautions:A POTENTIAL EXPLOSION HAZARD WHEN EXPOSED TO A SOURCE
OF IGNITION.

Exposure Controls

Respiratory Protection:FOR LEVELS UP TO 500 PPM USE NIOSH APPRVD CHEM
CARTRIDGE RESP W/ORG VAP CARTRIDGES, SUPPLIED-AIR RESP OR SCBA. FOR
LEVELS UP TO 1000 PPM USE NIOSH APPRVD CHEM CARTRIDGE RESP W/ORG
VAP CARTRIDGES & FUL L FACEPIECE. FOR LEVELS UP TO (SUPDAT)
Ventilation:PROVIDE EXPLOSION-PROOF VENTILATION AS NECESSARY TO CONTROL
EXPOSURES TO VAPORS.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
HYDROCARBON INSOLUBLE APRON.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VAP DENS: 3.1 (OF SOLVENT). SPILL PROC: EMPTY CNTNR OF SAME DOT
SPECIFICATION. ALL MATLS USED IN CLEAN UP PROCESS & THAT ARE
SUBSEQUENTLY TO BE DISCARDED ARE CONSIDERED TO BE HAZ WASTE. RESP
PROT: 200 0 PPM USE NIOSH APPRVD GAS MASK W/ORG CARTRIDGES,
SUPPLIED-AIR RESP W/FULL FACEPIECE/HOOD/HELMET/SCBA W/FULL
FACEPIECE.

Chemical Properties

Vapor Pres:4 @ 20C
Vapor Density:SUPDAT
Spec Gravity:1.01
Solubility in Water:APPRECIABLE
Appearance and Odor:REDDISH BROWN LIQUID; MILD ODOR.
Percent Volatiles by Volume:44

Stability

Stability Indicator/Materials to Avoid:YES
ALKALIES, OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NO*X, SO*X, CO*X, OTHER SULFUR
COMPOUNDS AT COMBUSTION TEMPERATURES.

Disposal

Waste Disposal Methods:COMPLY W/ALL FEDERAL, STATE & LOCAL LAWS & REGS
APPLIC TO PACKAGING, MANIFESTING, TRANSPORTING & DISPOSING OF HAZ
WASTE. INCINERATE AT A FACILITY LICENSED FOR DISPOSAL OF IGNITABLE
HAZ WASTE. EPA RCRA ID NUMBER: D001 (IGNITABLE) REFERENCE 40 CFR
261.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.